Attribute Label | Value |
---|---|
PDP Expert Advice | Diesel Fuel Consumption at 100% prime power load is 6 Liters per hour. |
Package Height (cm) | 85.00 |
Package Length (cm) | 180.00 |
Specifications Description | #html-body [data-pb-style=HT2F5CY]{justify-content:flex-start;display:flex;flex-direction:column;background-position:left top;background-size:cover;background-repeat:no-repeat;background-attachment:scroll}
Powered by FAW 4DW91-29D Engine
Power Factor: 4 Pole Partner alternators are designed to operate between 0.8 and 1 power factor. The alternator will be de-rated when operating below 0.8 power factor.
Engine Data Manufacturer: FAW Model: 4DW91-29D Engine Speed: 1500rpm Prime power: 21KW/28HP Standby power: 23KW/30HP Type: 4 cycle, In-line,4-cylinder Cooling: Water â cooled Aspiration: Naturally Aspirated Displacement: 2.54L Cylinder Bore* Stroke: 90mmÃ100mm Cylinder quantity: 4 Compression ratio: 17:1 Minimum Full Load Speed: 1500rpm Direction and rotation of flywheel: Anticlockwise Governing: Mechanical
Cooling System Coolant capacity-engine only: 6L Thermostat adjusting temperature (range): 83-95â Max. coolant temp. permitted_standby: 104â
Engine Weight: 220 kg
Alternator Data Model: DAC 184J Output power: 20 Kva Rated Current 0.8PF: 28A per phase AVR model: SX460 Phase and connection: 3 Phase 4 Wire Power factor(Cos Phi): 0.8 Exciter Stator Resistance: 20 Ohms at 22â Maximum Overspeed: 2250 Rev/Min Control System: Self Excited Insulation class: H Degree of protection: IP23 Voltage regulation: ±1.0% Winding Leads: 12 Winding Pitch: Two Thirds Waveform Distortion: No Loadï¼1.5% Non-Distorting Balanced Linear Loadï¼5.0% Stator Winding: Double layer Concentric Bearing: Single Exciter Rotor Resistance: 0.091 Ohms PER PHASE at 22â
Fuel Consumption @ Various Loads 50% of prime power: 3 LPH 75% of prime power: 4.5 LPH 100% of prime power: 6 LPH
Sound Attenuated Canopy – SAT
Our AMF control panel uses a Deep Sea control module. The Module is an Automatic Mains Fail controller for genset applications. The AMF panel is used where the local utility mains supply is backed up by an appropriately sized generating set. The AMF panel monitors the local mains supply; if this supply should fail, or fall outside pre-set limits the AMF panel will control the pre-heating, fuel solenoid and starting of the generating set either through relays and contacts or via engine ECU if available. The control panel is equipped as below:
Auto Mains Failure Control Panel:
DSE 4520 AMF Controller Key Features
LCD Display Metering
Shutdowns & Faults |
Specifications Notification | Standard Attenuation Noise Level: 75~80dB within 1m; 72~75dB within 7m. |
Tank Capacity | 55 L |
Introducing the MAC AFRIC 20 kVA, powered by the FAW 4DW91-29D engine, delivering 20kVA Prime Power (PRP). This unit features a single bearing, self-excited, brushless AVR-controlled alternator and a Deepsea Manual/AMF Control Panel. It also includes an integrated ATS (Auto Transfer Switch) and many more features detailed below.