Mecer 1200VA (720W) Inverter Battery Charger (UPS) - Intelligent Fan

Mecer 1200VA (720W) Inverter Battery Charger (UPS) - Intelligent Fan

Mecer Inverter 1200VA 720W LCD Screen Intelligent FAn
1.01 Reviews
R 282.71
🚚 Ships in 7-9 work days

Mecer Inverter 1200VA 720W LCD Screen Intelligent FAn

🛡️
Warranty
6-Month Limited Warranty.
↩️
Return Policy
Hassle-Free Exchanges & Returns for 7 Days.

Product Information

SKU69279577
Stock StatusIn Stock
Safe Checkout

Buy Now, Pay Later

Split your purchase into easy payments

Interest Rate0% Interest
Payment Period6 months
  • 15% deposit then pay monthly - that's only R 42.41 upfront!
  • No interest - you only pay the product price
  • Quick approval - decision within 1-2 business days
  • Secure - ID verification required for your protection

Please note that this unit will not turn on if not connected to at least one 12V battery.
The fan will turn off once batteries are fully charged!

Mecer 1200VA, 720W, 12V DC-AC Inverter.
Cables to connect the unit to a battery are included.
A 220V power cable is included to recharge the battery while the power is on.
May be used as an inverter (to power 220V devices such as TVs from a battery) or
a UPS (runs the device from the standard 220V power while the battery charges)

Not designed to run in a DB Board

External Battery Required

Features:
- Simulated sine wave inverter
- Built-in AVR for voltage regulation
- Wide input voltage range: 90-280 VAC
- 12VDC available
- Overload and short circuit protection
- LCD for comprehensive information

Specifications:
- MODEL Mecer IVR-1200LBK
- CAPACITY 1200 VA / 720 W
- POWER FACTOR 0.8
- Input Voltage range 90-280VAC

Line Mode:
- Output Voltage
- Bypass mode: 0utput voltage same as the input voltage
- AVR mode:Output voltage = Input voltage 1.2 at Input voltage - Output Frequency Same as input

Battery Mode:
- Output Voltage 230Vac +/-10%
- Transfer Time 20ms typical
- Waveform Modified Sine-wave

Overload Capability:
- Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
- Load >130% +/-15%, fault immediately.
- AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
- AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
- Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.

Short Circuit Protection:
- Line Mode Breaker
- Battery Mode Current limit +Firmware Protection

Battery:
- Battery Voltage 12VDC
- Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
- Polarity Reserve Protection Yes
- Charger available I/P range 90 280V

Charger:
- Constant Current Charger Voltage 14.3VDC +/-2%
- Floating Charge Voltage 13.7VDC +/-2%
- Maximum Charge Current 10A or 20A
- DC Start Voltage >11VDC

Physical:
- Dimension, D X W X H (mm) 350 x 90 x 300
- Net Weight (kgs) 4.5

Environment:
- Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
- Operating Temperature 0 degrees C to 40 degrees C
- Storage Temperature -15 degrees C to 50 degrees C

What's in the box
1 x Inverter Battery Charger

Please note that this unit will not turn on if not connected to at least one 12V battery.
The fan will turn off once batteries are fully charged!

Mecer 1200VA, 720W, 12V DC-AC Inverter.
Cables to connect the unit to a battery are included.
A 220V power cable is included to recharge the battery while the power is on.
May be used as an inverter (to power 220V devices such as TVs from a battery) or
a UPS (runs the device from the standard 220V power while the battery charges)

Not designed to run in a DB Board

External Battery Required

Features:
- Simulated sine wave inverter
- Built-in AVR for voltage regulation
- Wide input voltage range: 90-280 VAC
- 12VDC available
- Overload and short circuit protection
- LCD for comprehensive information

Specifications:
- MODEL Mecer IVR-1200LBK
- CAPACITY 1200 VA / 720 W
- POWER FACTOR 0.8
- Input Voltage range 90-280VAC

Line Mode:
- Output Voltage
- Bypass mode: 0utput voltage same as the input voltage
- AVR mode:Output voltage = Input voltage 1.2 at Input voltage - Output Frequency Same as input

Battery Mode:
- Output Voltage 230Vac +/-10%
- Transfer Time 20ms typical
- Waveform Modified Sine-wave

Overload Capability:
- Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
- Load >130% +/-15%, fault immediately.
- AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
- AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
- Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.

Short Circuit Protection:
- Line Mode Breaker
- Battery Mode Current limit +Firmware Protection

Battery:
- Battery Voltage 12VDC
- Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery
- Polarity Reserve Protection Yes
- Charger available I/P range 90 280V

Charger:
- Constant Current Charger Voltage 14.3VDC +/-2%
- Floating Charge Voltage 13.7VDC +/-2%
- Maximum Charge Current 10A or 20A
- DC Start Voltage >11VDC

Physical:
- Dimension, D X W X H (mm) 350 x 90 x 300
- Net Weight (kgs) 4.5

Environment:
- Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
- Operating Temperature 0 degrees C to 40 degrees C
- Storage Temperature -15 degrees C to 50 degrees C

What's in the box
1 x Inverter Battery Charger