Ps100(N1201Sa) 137 5M-2 7G Resistance Reactance Analyzer
Impedance Measurement Range: 1 ohm~1000 ohm @frequency less than 1300MHz; 1 ohm~300 ohm @frequency more than 1300MHz (Impedance Absolute Value).Click The Measurement Interface. Aluminum Alloy Shell Extends Service Life.
Note: For User Convenience, The Calibration Option Will Automatically Change To User Calibration Each Time It Is Calibrated. At The Same Time, In Order To Ensure The Integrity Of The Calibration, During The Calibration Process, The Automatic Shutdown Function Fails And Is Turned On Consistently.
The Attached Video Shows The Correct Method Of Opening The Device. The Keys On The Panel Are 1234 From Left To Right. You Need To Press 2 And 4 At The Same Time.
Power On And Off: Hold Down The Ctrl Key To Power Off, And Press The Power Switch Button. When The Instrument Is Powered On, Press And Hold (More Than 2s) The Switch Button. After Releasing, The Instrument Will Shut Down. When The Instrument Is Powered On, Press And Hold (More Than 2s) The Switch Button. After Releasing, The Instrument Will Shut Down.
Usage Recommendations: To Ensure The Accuracy Of Measurement And Calibration, The Instrument Must Be Warmed Up For At Least 15 Minutes. Try To Use Good Quality Rf Cables And Connectors.
Description:
Model: PS100
Working Frequency: 137.5MHz~2.7GHz
Stepped Frequency: 1kHz
Display: 2.4inch TFT with resolution 320x240(QVGA)
Power Consumption less than 1.5W
Charging Current: 400mA
Charging Port: USB
Auto Power Off: Settable 5-60minutes
Measured Parameters: Impedance, reactance, SWR and S11
Resolution: 4-digit readings
Frequency Accuracy: less than +/- 10ppm
Connector: SMA-K
Standing Wave Measurement Range:
1~65 @frequency less than 1300MHz
1~10 @frequency more than 1300MHz
S11(dB)Measurement Range: 0dB to -50dB
Error (Single-point measurement):
For Impedance: less than Impedance absolute value x 5% +/- 0.1ohm (Z less than 200 ohm, less than 1.5GHz)
For Standing Wave: less than Effective readings x 10% +/- 0.1
For S11: 0.1dB/5 (0dB to -10dB)
For (dB/ ): 1dB/10 (-10dB to -20dB); 5dB/20 (-20dB to -40dB)
Directivity: less than 35dB (140MHz to 2GHz after calibration); less than 30dB (2GHz to 2.7GHz)
Scanning Points: 280
Output Level: -18dBm
Working Temperature: 0 to 40
Atmospheric Pressure: 860hPa~1060hPa
Note: Different Batches May Have Differences In Product Appearance, Color, And Printed Characters, Which Will Not Affect The Use
With "RF VECTOR ANTENNA ANALYZER METER PS100" words
Material: Aluminum alloy
colour: Black
Package Contents:
1 x Antenna Analyzer
1 x Data Cable
1 x English Manual
Only the above package content, other products are not included.
Note: Light reflection and different displays may cause the color of the item in the picture a little different from the real thing. The measurement allowed error is +/- 1-3cm.
What's in the box
1 x Antenna Analyzer
1 x Data Cable
1 x English Manual