LAPP 1.0MM Panel Wire – 100M
Application range
Internal wiring of devices
Protected installation in and on lighting equipment
Signal systems in and on plaster in tubes
Product features
Flame-retardant according to IEC 60332-1-2
Spool: d1 = 18 mm; d2 = 200 mm; b = 85 mm
Norm references / Approvals
cable type certification acc. EN 50525-2-31
Product Make-up
The fine-wired copper conductor of bare copper strands in line with conductor class 5 acc. IEC 60228
Core insulation: Based on PVC
Technical Data
Classification ETIM 5: ETIM 5.0 Class-ID: EC000993
ETIM 5.0 Class-Description: Single core cable
Classification ETIM 6: ETIM 6.0 Class-ID: EC000993
ETIM 6.0 Class-Description: Single core cable
Conductor stranding: Fine wire according to VDE 0295 Class 5/ IEC 60228 Class 5
Minimum bending radius: According to EN 50565-1
4 x outer diameter (OD) for normal use; 2 x OD for cautions
bending
Nominal voltage: U0/U: 300/500 V
Test voltage: 2000 V
Current rating: VDE 0298 Part 4
EN 50565-1/ VDE 0298-565-1
Temperature range: Fixed installation: -40°C to +80°C
Moved: +5°C to +70°C
What’s in the box
100 x Panel Wire
Reviews