MECER
MECER WINNER PRO 3000VA 2U ON-LINE RACKMOUNT UPS
Mecer 3000VA / 2400W 2U ON-LINE SINE WAVE Rackmountable UPS (with Monitoring Software) -Black
Product Code ME-3000-WPRU
EAN Code ME-3000-WPRU
Features
True double-conversion online UPS
Wide input voltage range (110-300 VAC)
Input power factor correction 0.99
Output power factor 0.8
Converter mode available
ECO mode operation for energy saving (only available for 1-3KVA)
Hot-swappable battery design only available for 1-3KVA
Generator compatible
Adjustable charging current via LCD or software (1A ~ 6A)
Specifications
Colour
Black
PHASE
Single phase with ground
CAPACITY
3000 VA / 2400 W
INPUT
Voltage Range
Low Line Transfer
160 VAC/140 VAC/120 VAC/110 VAC 5% (Ambient Temp.<35 C)
(based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
Low Line Comeback
175 VAC /155 VAC/ 135 VAC /125 VAC 5 % (Ambient Temp.<35 C)
(based on load percentage 100% – 80 % / 80 % – 70 % / 70 – 60 % / 60 % – 0)
High Line Transfer
300 VAC 5 %
High Line Comeback
290 VAC 5 %
Frequency Range
40Hz ~ 70 Hz
Power Factor
? 0.99 @ nominal voltage
OUTPUT
Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
1%
Frequency Range (Synchronized Range)
47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)
50 Hz 0.25 Hz or 60Hz 0.3 Hz
Current Crest Ratio
3:1
Harmonic Distortion
? 3 % THD (Linear Load),
? 6% THD (non-linear load)
Transfer Time
AC Mode to Batt. Mode
Zero
Inverter to Bypass
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
EFFICIENCY
AC Mode
90%
Battery Mode
88%
BATTERY
Battery Type
12 V / 9 Ah
Numbers
6
Typical Recharge Time
4 hours recover to 90% capacity
Charging Voltage
82.1 VDC 1%
INDICATORS
LCD Panel
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Dimension, D x W x H (mm)
630 x 483 x 88 [2U] Net Weight (kgs)
29.3
ENVIRONMENT
Humidity
20-90 % RH @ 0- 40 C (non-condensing)
Noise Level
Less than 50dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows ?
2000/2003/XP/Vista/ 2008, Windows? 7/8, Linux, Unix, and MAC
Optional SNMP (SNMP NETWORK CARD need to be purchased separately)
Power management from SNMP manager and web browser
NOTE 1: Derate to 80% of capacity in CVCF mode or when the output voltage is adjusted to 200/208VAC.
NOTE 2: If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
What’s in the box
1 x UPS Unit
1 x Power Cable
1 x VGA Cable
1 x MALE TO FEMALE EXTENSION POWER CORD IEC C13-C14Â (From UPS to PC)
1 x USB Cable (From UPS to PC)
1 x Driver Disk
1 x User Guide