Digital Temperature Humidity Controller Thermostat switch Thermometer Hygrometer Regulator DC 6-30V 10A XY-WTH1
Please Note! This is not a Humidifier BUT an appliance to control, switch on/off a humidifier/heater/cooler
This unit has both Temperature AND Humidity Function Control
Temperature Controller Functions:
The automatic identification of work mode:
The system automatically according to the start/stop temperature, identify work mode;
Start temperature > stop temperature, cooling mode ‘C’.
Start temperature < stop temperature, heating mode 'H'.
Cooling mode:
When the temperature ? Start temperature, relay conduction, red led on, refrigeration equipment begin to work;
When the temperature ? Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
Heating mode:
When the temperature ? Start temperature, relay conduction, red led on, heating equipment begin to work;
When the temperature ? Stop temperature, relay disconnect, red led off, heating equipment stop to work;
Temperature correction function OFE (-10.0 ~ 10 Degrees Celsius):
The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;
How to set the start/stop temperature:
– In the running interface, Long Press TM+ key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM- key, to be modified, waiting for 6s automatic exit and save;
– In the running interface, Long Press TM- key more than 3 seconds, into the stop temperature settings interface, can be modified by TM+ TM- key, to be modified after the parameters, waiting for 6s automatic exit and save;
The Humidity Controller Functions:
-
The automatic identification of work mode:
The system automatically according to the start/stop humidity, identify work mode;
Start humidity> stop humidity, dehumidification mode ‘D’.
Start humidity< stop humidity, humidification mode 'E'. -
Dehumidification mode:
When the humidity? Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
When the humidity? Stop humidity, relay disconnect, green led off, dehumidification equipment stop to work; -
Humidification mode:
When the humidity? Start humidity, relay conduction, green led on, humidification equipment begin to work;
When the humidity? Stop humidity, relay disconnect, green led off, humidification equipment stop to work; -
Humidification correction function RH (-10.0 ~ 10%):
The system is working for a long time and may be biased, through this function correction, the actual humidity = measuring humidity + calibration value;
How to set the start/stop humidity:
– In the running interface, Long Press ‘ RH+ ‘ key more than 3 seconds, into the start humidity settings interface, can be modified by RH + RH – key, to be modified, waiting for 6s automatic exit and save;
– In the running interface, Long Press ‘ RH-‘ key more than 3 seconds, into the stop humidity settings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;
- Serial port control (microcontroller TTL level communication)
Communication standard: 9600bps data bits: 8
Stop bit :1
What’s in the box
1x Hygrometer
Reviews
There are no reviews yet.