Bluetooth Smart built-in:
The wireless solution to set-up, monitor, update and synchronise SmartSolar Charge Controllers.
VE.Direct:
For a wired data connection to a Color Control GX, other GX products, PC or other devices
Ultra-fast Maximum Power Point Tracking (MPPT):
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra-fast MPPT controller will improve energy harvest by up to 30 % compared to PWM charge controllers and by up to 10 % compared to slower MPPT controllers.
Load output:
Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a pre-set voltage (48 V model: interface with a relay). Alternatively, an intelligent battery management algorithm can be chosen: see Battery Life. The load output is short circuit proof.
Battery Life: intelligent battery management:
When a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will continually be cycled between a ‘partially charged’ state and the ‘end of discharge’ state. This mode of operation (no regular full recharge) will destroy a lead-acid battery within weeks or months. The Battery Life algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i.e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100 %. From that point onwards, the load disconnect level will be modulated so that a nearly 100 % recharge is achieved about once every week.
Programmable battery charge algorithm – See the software section on our website for details
Day/night timing and light dimming option – See the software section on our website for details
Internal temperature sensor – Compensates absorption and float charge voltage for temperature.
Optional external battery voltage and temperature sensing via Bluetooth:
A Smart Battery Sense or a BMV-712 Smart Battery Monitor can be used to communicate battery voltage and temperature to one or more SmartSolar Charge Controllers.
Fully discharged battery recovery function:
Will initiate charging even if the battery has been discharged to zero volts.
Will reconnect to a fully discharged Li-ion battery with integrated disconnect function.
Feature highlights common to all models
Ultra-fast Maximum Power Point Tracking (MPPT).
Advanced Maximum Power Point Detection in case of partial shading conditions.
Outstanding conversion efficiency.
Natural convection cooling.
Automatic battery voltage recognition.
Flexible charge algorithm.
Over temperature protection and power derating when temperature is high.
Battery voltage: 12/24/48V
Rated charge current: 20 A
Nominal PV power, 12 V 1a,b): 290W
Nominal PV power, 24 V 1a,b): 580W
Nominal PV power, 48 V 1a,b): 1160W
Max. PV short circuit current 2): 20A
Automatic load disconnect: Yes
Max. PV open circuit voltage: 100V
Peak efficiency: 98%
Self-consumption – load on: 26 / 20 / 19 mA
Self-consumption – load off: 10 / 8 / 7 mA
Charge voltage ‘absorption’: 14,4 V / 28,8 V / 57,6 V (adj.)
Charge voltage ‘float’: 13,8 V / 27,6 V / 55,2 V (adj.)
Charge algorithm: Multi-stage adaptive
Temperature compensation: -16 mV / C resp. -32 mV / C
Max. continuous load current: 20 A / 20 A / 1 A
Low voltage load disconnect: 11,1 V / 22,2 V / 44,4 V or 11,8 V / 23,6 V / 47,2 V or Battery Life algorithm
Low voltage load reconnect: 13,1 V / 26,2 V / 52,4 V or 14 V / 28 V / 56 V or Battery Life algorithm
Protection: Output short circuit / Over temperature
Operating temperature: -30 to +60 C (full rated output up to 40 C)
Humidity: 95% (non-condensing)
Data communication port VE.Direct (see the data communication white paper on our website)
Enclosure:
Protection category: IP43 (electronic components), IP22 (connection area)
Standards:
Safety: EN/IEC 62109-1, UL 1741, CSA C22.2
1a) If more PV power is connected, the controller will limit input power.
1b) The PV voltage must exceed Vbat + 5 V for the controller to start.
Thereafter the minimum PV voltage is Vbat + 1 V
2) A PV array with a higher short circuit current may damage the controller.
What’s in the box
1x Victron BlueSolar MPPT 100/20
User manual
Reviews